Understanding the 45-Degree Daylight Rule
The 45-degree rule is the primary metric planning officers use to protect neighbouring properties from excessive loss of daylight and visual overshadowing.
The officer draws a 45-degree diagonal line on the horizontal site plan from the midpoint of the nearest neighbouring habitable room window (such as a living room or bedroom). If your proposed two-storey extension intersects this 45-degree line, the application is likely to be refused unless modified.
| Planning Standard | Permitted Development Limit | Full Planning Practice | Common Solution if Breached |
| Maximum Rear Depth | 3.0 metres maximum | 3.0m - 4.5m (subject to 45° rule) | Reduce first-floor depth while keeping ground floor 4m+ |
| Distance to Rear Boundary | 7.0 metres minimum | Council policy dependent (typically 10m+) | Reconfigure ground layout or reduce projection |
| Daylight Protection | Implicit in 3.0m depth limit | Strict 45-Degree test enforced | Splay corner walls or chamfer upper roof pitch |
| First-Floor Side Windows | Obscure glazed (Pilkington Level 3+) & fixed | Obscure glazed unless non-habitable | Install rooflights angled high above floor level |
- Horizontal 45-degree check: Measured from the centre of neighbour's nearest habitable window.
- Vertical 45-degree check: Measured from window cills in architectural facade drawings.
- Habitable room definition: Applies to living rooms, dining rooms, and bedrooms (excludes bathrooms and hallways).
- Stepped footprint design: Stepping the first-floor back helps clear the 45-degree angle.
Two-Storey Permitted Development Criteria
You can build a double-storey rear extension under Permitted Development without full planning permission, provided your property satisfies strict statutory limits.
The extension must not extend more than 3.0 metres beyond the original rear wall, cannot sit within 7.0 metres of the rear boundary, and must match the roof pitch of the existing dwelling. Furthermore, any upper-floor side-facing windows must be fitted with obscure glazing and non-opening below 1.7 metres from the floor.
Managing Window Overlooking and Privacy Distances
Local planning authorities enforce minimum privacy separation distances, typically demanding at least 21 metres between facing rear first-floor windows of neighbouring houses.
First-floor balconies and open roof terraces are prohibited under Permitted Development because they permit direct overlooking into neighbouring private gardens. Juliet balconies with flat glass balustrades set flush to exterior walls are generally accepted.