Trench Fill Foundations: Speed and Simplicity
Trench fill foundations simplify substructure construction. The excavator digs a narrow trench, typically 450mm to 600mm wide, down to firm bearing ground. Ready-mix concrete is then poured directly into the trench to within 150mm of ground level.
By filling the trench almost entirely with mass concrete, trench fill eliminates the slow and hazardous task of sending bricklayers down into deep trenches to lay blockwork up to ground level. It also avoids trench collapse in unstable sandy or wet ground.
| Foundation Type | Ground Conditions | Excavation Depth | Primary Benefit |
| Trench Fill | Firm clay, chalk, or gravel | 1.0m to 2.2m | Fastest build speed; no deep trench bricklaying |
| Traditional Strip | Stable rock or dense dry gravel | 0.75m to 1.2m | Lowest concrete material consumption |
| Reinforced Raft | Soft, variable, or made ground | 0.4m to 0.8m | Eliminates differential settlement risks |
| Piled Ground Beam | Tree roots in deep shrinkable clay | 2.5m to 10.0m | Guaranteed stability in deep unstable soils |
- Reduced labour: No bricklaying required below ground level.
- Fast cycle time: Dug and poured in two days, ready for above-ground masonry.
- Concrete volume: Uses significantly more ready-mix concrete than shallow strip footings.
- Heave vulnerability: Deep clay trenches require side void former boards.
Traditional Wide Strip Foundations
Traditional strip footings involve pouring a shallow 250mm to 300mm deep concrete bed at the bottom of the trench. Bricklayers then lay engineering bricks or high-density concrete blocks in two parallel skins up to damp proof course (DPC) level.
Strip footings use far less concrete than trench fill, making them economical where labour is cheap or concrete pump access is impossible. However, trenches must remain open and stable for several days during bricklaying.
Engineered Raft Foundations for Poor Ground
When soil investigations encounter variable made ground, old landfill, or very soft alluvial silts, standard strip footings risk uneven differential settlement. In these circumstances, structural engineers design a reinforced concrete raft foundation.
A raft is a solid reinforced concrete slab (typically 200mm to 300mm thick) covering the entire building footprint, strengthened with edge downstand beams. The raft spreads the building load evenly across the ground, functioning like a boat floating on the subsoil.